Now in its fourth generation, the V2108 is Quested’s longest standing product and sets the benchmark in our nearfield monitoring range. When it was launched in 1988, the 2108 instantly built an enviable reputation with some of the world’s most critical and demanding users. Whilst always staying true to its origins, the V2108 has evolved over the past thirty years, with improvements in both transducers and amplification that keep pace with the ever-changing needs of the industry. This has allowed it to earn a lifetime of trust with producers and artists around the globe, whilst staying young at heart. Suited to standalone monitoring or multi-channel applications, the V2108 is our most powerful and versatile nearfield reference.
TECHNICAL SPECIFICATION
Dimensions: 340 x 400 x 365mm (w x h x d)
Weight: 23kg / 50.5lb
Drivers: Low Frequency 1 x 200mm(8″) LF
High Frequency: soft dome – 1 x 28mm (1. 1/8″)
Maximum SPL: 108.5dB continuous pink noise. Absolute peak 116dB music
Frequency Response: 45 Hz – 20 kHz ± 2dB / 38 Hz- 22 kHz -6dB
INPUT
Connector: XLR3 type-Female
Impedance: 10k Electronically balanced with RF filters
Wiring: Pin 1 ground, Pin 2 hot, Pin 3 cold
Sensitivity: Rear mounted 10 position rotary switch calibrated in 2dB steps
Minimum sensitivity +7dBu for 100dB SPL @ 1m
Maximum sensitivity -11dBu for 100dB SPL @ 1m
FILTERS
Subsonic: -3dB @ 20Hz, 24dB/oct
Crossover Point: 1k4H, 24dB/oct
User LF EQ: 4 position rear mounted selector to select FLAT for normal use. -3/- 9dB for cut below 40Hz, 0, +1dB.
User HF EQ 3 position rear mounted switch to select FLAT for normal use, CUT/LIFT +/-1dB above 2k5Hz.
POWER AMPLIFIERS
HF output power: > 200W rms continuous (Note 1)
LF output power: > 200W rms continuous (Note 1)
THD: < 0.03% at levels up to 1dB below clip, 20Hz – 20kHz. typ 0.005% @ 20W rms 1kHz.
Hum + Noise: > -100dB referred to clip
Note 1: The continuous rating is for a period not exceeding 5 minutes with unrestricted airflow (>100mm clearance) around the amplifier rear panel and ambient temperatures is <30 Degrees C
INDICATION
Power on: Front mounted LED (flashing blue) indicates power applied and warm-up cycle.
Optimum Performance: Front mounted LED lights constant blue.
Overload: Front mounted LED flashes red (HF 1dB below signal clip, LF 2dB below signal clip)
Thermal Protection: Front mounted LED turns red, signal is muted and amplifier switches to standby mode during thermal protection cooling cycle. Normal operation resumes when amplifier temperature drops by 20 o C.
POWER REQUIREMENTS
Voltage: Set by internal plugs: nominal 115V or 230V @ 50-60Hz AC.
230V setting: Min 160V (restricted output power): Max 263V
115V setting: Min 80V (restricted output power): Max 132V
CONSUMPTION
Quiescent 32W, Typical use 92W.